Application:
These cables are used for transfer of signals in railway networks in signalling circuits to connect the signalling equipment.
Construction |
- |
In multiples of Cores / Pairs / Quads |
Conductor |
- |
Solid / stranded wire(s) of annealed high conductivity copper. |
Insulation |
- |
PVC / Polyethylene / XLPE |
Core Formation |
- |
Insulated Cores / Pairs / Quads laid-up together |
Inner / Intermediate Sheath |
- |
PVC / Polyethylene / HFFR |
Shielding |
- |
Dual layer of Aluminium Wire |
Additional Covering |
- |
Non-Hygroscopic Tape / Chromium Bromate Tape |
Armouring |
- |
Galvanized Round Wire / Strip / Double Steel Tape. |
Outer Sheath |
- |
PVC / Polyethylene / HFFR |
SNCF CT 445, NF F 55-698, IRS S 63, IRS S76, IRS TC 30, IRS SPC_TC_72, IEC 60332-1-2
Temperature Range |
- |
-30°C to +90°C |
Insulation Resistance |
- |
≥5000 MΩ.km |
Dielectric Strength |
- |
4.5kV |
Mutual Capacitance at 800Hz |
- |
≤ 55 nF/km |
Capacitance Unbalance |
- |
400 pF / 500m |
Characteristic Impedance |
- |
i) For 20 to 45 KHz : 120±10Ω |
ii) For 45 to 80 KHz : 115±10Ω |
Linera Attenuation |
- |
i) For 20 to 45 KHz : ≤ 2.5 dB/km |
ii) For 45 to 80 KHz : ≤ 3 dB/km |
Features:
Excellent resistance to high and low temperature. |
Resistance to oil, damp and humid weather conditions. |
Low reduction factor. |
Suitable for use on AC systems (Earthed or unearthed) for rated voltage upto 1100 volts. |
Suitable for use on DC systems for rated voltage upto 1500 volts. |