Application:
These cables are designed for connecting photovoltaic system components inside and outside of buildings and equipment with high mechanical requirements and extreme weather conditions.
Product Construction:
Conductor |
- |
Flexible tinned copper conductor as per IEC 60228 Class 5.
(1.50 SQ.MM. TO 300 SQ.MM.) |
Insulation |
- |
Cross-linked, Halogen free Polyolefin compound. |
Sheath |
- |
Cross-linked, Halogen free Flame retardant UV Resistant Polyolefin compound, Black. |
Reference Standards:
BS EN 50618 (Type-H1Z2Z2-K) (formerly PV-1F according to 2PfG 1169)
Mechanical Properties:
-- Minimum Bending Radius: 5×OD (fixed), 15×OD (flexing) |
-- Dynamic Penetration: According to EN 50618, Annex D |
-- Tensile Strength Of Insulation and Jacket: 8 N/mm2 |
-- Elongation Of Insulation And Jacket: 125% |
-- Anticipated Period Of Use: 25 years |
-- Ovality:≤15% |
Chemical Properties –
-- Ozone Resistance: According to; EN 50396:2005 |
-- Weathering- UV Resistance (Resistance on sheath): According to Annexure E as per EN 50618:2014. |
-- Ammonia resistant. |
-- Very good resistance to oils and chemicals. |
-- High wear and robust, abrasion resistant. |
Electrical Properties:
-- Rated Voltage U0/U: 1/1 kV AC; 1.5/1.5 kV DC |
-- Maximum Permitted DC Voltage: 1.8 kV DC (conductor/conductor, non earthed system, circuit not under load) |
-- Maximum Voltage: 1.2KV (AC), 1.8KV (DC) |
-- Insulation Resistance: As per EN 50618:2014 |
-- Spark Test: 6000 Vac (8400 Vdc) |
-- Voltage Withstand: 6500 Vac for 5 min |
Thermal Properties –
-- Ambient Temperature: -40℃ to +90℃ |
-- Maximum Temperature At Conductor: 120℃ (20000h) according to EN 60216-1 |
-- Short Circuit Temperature: 250℃/5 sec |
-- Thermal Endurance Test: According to EN 60216-2 (temperature index +120° C) |
-- Damp-Heat Resistance: According to EN 50618, Table 2 with 85% humidity (test acc. to EN 60068-2-78) |
Fire Performance:
Flame retardant according to IEC 60332-1-2 |
Low smoke emission according to EN 61034-2 |
Halogen free according to IEC 50525-1 |